feat(fase1): assessment-method encoding — persisted dimension-scoped example + validator rule (F1)

This commit is contained in:
Kjell Tore Guttormsen 2026-07-07 08:15:44 +02:00
commit 69ca508677
4 changed files with 171 additions and 0 deletions

View file

@ -0,0 +1,19 @@
---
type: index
okf_version: 0.1
title: "Energi — vurderingsmetode-encodinger (MAF-repo-lokalt)"
description: "Persisterte, dimensjon-scopede vurderingsmetode-encodinger for energi-dimensjonen, navigerbare via OKF."
dimension: energi
tags: [metode, encoding, energi, IPMVP]
timestamp: 2026-07-06
---
# Energi — vurderingsmetode-encodinger
Et persistert, **MAF-repo-lokalt** metode-bundle. Det bor her (ikke i `shared/`) fordi `shared/` er
et PULL-ONLY subtree som ikke kan bære `dimension:`-frontmatter herfra. Bundelet encoder ≥1
vurderingsmetode mot referanse-domenet (energieffektivisering), dimensjon-scopet så
`okf.bundle_context(..., dimension="energi")` navigerer den (progressiv disclosure), og en annen
dimensjon utelater den.
- [IPMVP Option A — energi-metode](metode-ipmvp-a.md)

View file

@ -0,0 +1,29 @@
---
type: methodology
title: "IPMVP Option A — Retrofit Isolation, Key Parameter Measurement (energi)"
description: "M&V-metoden for å verifisere energibesparelsen fra ett isolert tiltak: mål nøkkelparameteren (effekt), estimér resten (driftstimer). Dimensjon-scopet encoding."
dimension: energi
methodology: IPMVP
option: A
tags: [IPMVP, M&V, EVO, energi, retrofit-isolation]
timestamp: 2026-07-06
---
# M&V-metode: IPMVP Option A (energi-dimensjon)
ENERGI-METODE-IPMVP-A-SENTINEL — denne encodede metoden er dimensjon-scopet til `energi`, så den
når kun agent-konteksten når kjøringen scopes til energi-dimensjonen.
**IPMVP** (International Performance Measurement and Verification Protocol) er konsensus-rammeverket
for å måle og verifisere energibesparelser, eid av **EVO** (Efficiency Valuation Organization).
Kjerneinnsikten: besparelse er en **kontrafaktisk** størrelse — den *beregnes*
(`Baseline Rapportering ± justeringer`), den måles ikke direkte.
## Option A — Retrofit Isolation: Key Parameter Measurement
Måler nøkkelparameteren (typisk effekt) på det berørte utstyret; øvrige parametere (typisk
driftstimer) **estimeres**. Fordi driftstimene er stipulert — ikke fullmålt — er den forsvarlige
verifiserte besparelsen **mer konservativ** enn en generisk øvre grense: en andel av tiltakets
kostnad som ligger UNDER den generiske policy-taket. Denne strammere, metode-spesifikke grensen er
kodifisert som en egen validator-stage (`validator._ENERGY_METHOD_MAX_FRACTION`), uavhengig av det
generiske P90-taket.

View file

@ -37,6 +37,15 @@ MAX_SAVING_FRACTION = 0.30
"""Policy cap: at most 30% of an affected item's cost is realistically recoverable as a
saving. The LP bounds the feasible saving by this fraction."""
_ENERGY_METHOD_MEASURE = "energy_efficiency"
_ENERGY_METHOD_MAX_FRACTION = 0.15
"""Step 9 (SC7-B): the IPMVP Option A method-specific cap. Option A measures only the KEY parameter
and STIPULATES the rest (operating hours), so the defensibly-verifiable saving is more conservative
than the generic policy cap deliberately STRICTER than ``MAX_SAVING_FRACTION`` so this rule is an
INDEPENDENT gate: it can reject a proposal the generic P90 stage passes (not redundant). The concrete
fraction is calibrated against the reference domain; the CONDITION (a method-scoped stricter cap) is
the encoded rule. Returns the same ``Rejection`` type a validator stage, not a new gate."""
_MC_SAMPLES = 512
_MC_SEED = 20260624
@ -126,6 +135,21 @@ def validate_proposal(proposal: SavingsProposal) -> ValidatedProposal | Rejectio
proposal=proposal,
reason=f"claimed saving {proposal.claimed_saving_nok:.0f} exceeds P90 feasible {p90:.0f}",
)
# Stage 5 (Step 9, SC7-B): a method-specific rule STRICTER than the generic cap. A proposal in
# the energy method (IPMVP Option A) must clear a lower, method-scoped feasible — an INDEPENDENT
# gate that can reject a proposal the P90 stage passed. Same ``Rejection`` type, not a new gate.
if proposal.measure == _ENERGY_METHOD_MEASURE:
method_feasible = _ENERGY_METHOD_MAX_FRACTION * sum(
it.total for it in proposal.affected_items
)
if proposal.claimed_saving_nok > method_feasible:
return Rejection(
proposal=proposal,
reason=(
f"claimed {proposal.claimed_saving_nok:.0f} exceeds the {_ENERGY_METHOD_MEASURE} "
f"method cap {method_feasible:.0f} (stricter than the generic P90)"
),
)
return ValidatedProposal(proposal=proposal, p10=p10, p50=p50, p90=p90, nominal_feasible=nominal)