docs: describe solution T through the cash flow, S53 and S54

Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com>
This commit is contained in:
Kjell Tore Guttormsen 2026-11-13 00:37:50 +01:00
commit e0db6ab4b7
Signed by: ktg
SSH key fingerprint: SHA256:JakMjO6FTBBzN0Bhfj9saOoEjaFxlSdYuZQQpM/lF9Q
3 changed files with 37 additions and 13 deletions

View file

@ -84,3 +84,15 @@ All notable changes to this project will be documented in this file.
made-up sets for S51–S54 without a difference. Six clarifications (70–75) in chapter 16 of the specification
say how chapter 17 is read where the text was silent. Solution T is not taken through the cash flow or the
verdicts yet, and no result for the hypothesis has been computed.
- Solution T through the power system and the cash flow (`kontantstrom.py`): everything per module, renewable
modules with their own portfolio as in C, the nuclear modules of T-K on shared units as in B, and the fixed
cost of a new nuclear country counted to the first unit. The loss of demand of chapter 17.3 enters the
revenue and the disconnection arm of S47 (`regn_program(..., bortfall=...)`); without a loss every figure is
unchanged. Emissions "with deduction" (S53) and cooling water (S54) are put together over a programme for
all seven solutions (`miljo.py`). A new independent reader coded the same from the specification alone:
1 778 made-up paths through both codes without a difference, and the two sensitivities that are switches in
both. Six clarifications (76–81) in chapter 16 settle what the text left open
(`modell/fagfellevurdering-utkast-2-og-3.md`, part 11). The levelised cost, ownership, scale and verdicts
refuse solution T and a loss of demand until chapter 17 is taken through them. No result has been computed.
- Present values are now exactly rounded sums. As dot products the same computation did not give the same last
digit every time, for every solution. A test runs the same computation six times and requires equal numbers.